Update for PWR CTRL Limits #884

Merged
muellerr merged 2 commits from change-pwr-ctrl-limits into main 2024-04-10 10:48:13 +02:00
2 changed files with 9 additions and 8 deletions

View File

@ -20,6 +20,12 @@ will consitute of a breaking change warranting a new major release:
- Reverted lower OP limit of `PLOC` to -10°C.
- All pointing laws are now allowed to use the `MEKF` per default.
- Changed limits in `PWR Controller`.
- PUS time service: Now dumps the time before and after relative timeshift or setting absolute time
## Added
- PUS timeservice relative timeshift.
# [v7.7.4] 2024-03-21
@ -27,16 +33,11 @@ will consitute of a breaking change warranting a new major release:
- Rotational rate limit for the GS target pointing is now seperated from controller limit. It
is also reduced to 0.75°/s now.
- PUS time service: Now dumps the time before and after relative timeshift or setting absolute time
## Fixed
- Fixed wrong sign in calculation of total current within the `PWR Controller`.
## Added
- PUS timeservice relative timeshift.
# [v7.7.3] 2024-03-18
- Bumped `eive-fsfw`

View File

@ -57,9 +57,9 @@ class PowerController : public ExtendedControllerBase, public ReceivesParameterM
float batteryMaximumCapacity = 2.6 * 2; // [Ah]
float coulombCounterVoltageUpperThreshold = 16.2; // [V]
double maxAllowedTimeDiff = 1.5; // [s]
float payloadOpLimitOn = 0.90; // [%]
float payloadOpLimitLow = 0.75; // [%]
float higherModesLimit = 0.6; // [%]
float payloadOpLimitOn = 0.80; // [%]
float payloadOpLimitLow = 0.65; // [%]
float higherModesLimit = 0.60; // [%]
// OCV Look-up-Table {[Ah],[V]}
static constexpr uint8_t LOOK_UP_TABLE_MAX_IDX = 99;