2020-12-29 11:29:03 +01:00
|
|
|
# -*- coding: utf-8 -*-
|
|
|
|
"""
|
|
|
|
@file tmtcc_tc_pdu2.py
|
|
|
|
@brief PDU2 tests
|
2021-08-17 10:37:13 +02:00
|
|
|
@details PDU2 is mounted on the X2 slot of the P60 dock
|
2020-12-29 11:29:03 +01:00
|
|
|
@author J. Meier
|
|
|
|
@date 17.12.2020
|
|
|
|
"""
|
2021-05-17 17:42:04 +02:00
|
|
|
from tmtccmd.config.definitions import QueueCommands
|
2021-07-24 14:58:47 +02:00
|
|
|
from tmtccmd.tc.packer import TcQueueT
|
2020-12-29 11:29:03 +01:00
|
|
|
from gomspace.gomspace_common import *
|
|
|
|
from gomspace.gomspace_pdu_definitions import *
|
2021-09-07 14:51:50 +02:00
|
|
|
|
|
|
|
|
|
|
|
class Pdu2OpCodes(enum.Enum):
|
|
|
|
ACS_SIDE_B_ON = "1"
|
|
|
|
ACS_SIDE_B_OFF = "2"
|
|
|
|
PRINT_SWITCH_STATE = "17"
|
2020-12-29 11:29:03 +01:00
|
|
|
|
|
|
|
|
|
|
|
class PDU2TestProcedure:
|
|
|
|
"""
|
|
|
|
@brief Use this class to define the tests to perform for the PDU2.
|
|
|
|
@details Setting all to True will run all tests.
|
|
|
|
Setting all to False will only run the tests set to True.
|
|
|
|
"""
|
2021-02-06 16:35:53 +01:00
|
|
|
all = False
|
2020-12-29 11:29:03 +01:00
|
|
|
reboot = False
|
|
|
|
read_gnd_wdt = False
|
|
|
|
gnd_wdt_reset = False
|
|
|
|
ping = False
|
2021-02-11 08:18:42 +01:00
|
|
|
channel_2_off = False # Reaction wheels 5V
|
|
|
|
read_temperature = True
|
|
|
|
read_channel_2_state = False # Reaction wheels 5V
|
2021-03-19 17:50:09 +01:00
|
|
|
read_cur_lu_lim_0 = False # OBC
|
2021-02-11 08:18:42 +01:00
|
|
|
channel_2_on = False # Reaction wheels 5V
|
2020-12-29 11:29:03 +01:00
|
|
|
invalid_table_id_test = False # Test to check if software properly handles invalid table ids
|
|
|
|
invalid_address_test = False # Test to check if software properly handles invalid addresses
|
2021-02-06 16:35:53 +01:00
|
|
|
invalid_parameter_size_test = False
|
2021-02-11 08:18:42 +01:00
|
|
|
request_hk_table = False
|
2020-12-29 11:29:03 +01:00
|
|
|
|
|
|
|
|
2021-08-17 11:49:37 +02:00
|
|
|
def pack_pdu2_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "Testing PDU2"))
|
2020-12-29 11:29:03 +01:00
|
|
|
|
2021-09-07 14:51:50 +02:00
|
|
|
if op_code == Pdu2OpCodes.ACS_SIDE_B_ON.value:
|
2021-08-17 11:49:37 +02:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Turn ACS Side B on"))
|
2021-09-07 15:45:05 +02:00
|
|
|
command = pack_set_param_command(
|
|
|
|
object_id, PDUConfigTable.out_en_7.parameter_address,
|
|
|
|
PDUConfigTable.out_en_7.parameter_size, Channel.on
|
|
|
|
)
|
2021-08-17 11:49:37 +02:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
return tc_queue
|
2021-09-07 14:51:50 +02:00
|
|
|
if op_code == Pdu2OpCodes.ACS_SIDE_B_OFF.value:
|
2021-08-17 11:49:37 +02:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Turn ACS Side B off"))
|
2021-09-07 15:45:05 +02:00
|
|
|
command = pack_set_param_command(
|
|
|
|
object_id, PDUConfigTable.out_en_7.parameter_address,
|
|
|
|
PDUConfigTable.out_en_7.parameter_size, Channel.off
|
|
|
|
)
|
2021-08-17 11:49:37 +02:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
return tc_queue
|
2021-09-07 14:51:50 +02:00
|
|
|
if op_code == Pdu2OpCodes.PRINT_SWITCH_STATE.value:
|
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Print Switch Status"))
|
|
|
|
command = generate_action_command(
|
2021-09-07 16:10:40 +02:00
|
|
|
object_id=object_id, action_id=GomspaceDeviceActionIds.PRINT_SWITCH_STATE
|
2021-09-07 14:51:50 +02:00
|
|
|
)
|
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
2020-12-29 11:29:03 +01:00
|
|
|
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.reboot:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Reboot"))
|
2021-08-17 11:49:37 +02:00
|
|
|
command = pack_reboot_command(object_id)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.read_gnd_wdt:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Reading ground watchdog timer value"))
|
2021-09-07 14:51:50 +02:00
|
|
|
command = pack_get_param_command(
|
|
|
|
object_id, TableIds.hk, PDUHkTable.wdt_gnd_left.parameter_address,
|
|
|
|
PDUHkTable.wdt_gnd_left.parameter_size
|
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.gnd_wdt_reset:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing ground watchdog reset"))
|
2021-08-17 11:49:37 +02:00
|
|
|
command = pack_gnd_wdt_reset_command(object_id)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.ping:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Ping Test"))
|
2020-12-29 11:29:03 +01:00
|
|
|
ping_data = bytearray([0, 1, 2, 3, 4, 5, 6, 7, 8, 9])
|
2021-08-17 11:49:37 +02:00
|
|
|
command = pack_ping_command(object_id, ping_data)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.channel_2_on:
|
2021-09-07 14:51:50 +02:00
|
|
|
tc_queue.appendleft(
|
|
|
|
(QueueCommands.PRINT, "PDU2: Testing setting output channel 2 on (TCS Heater)")
|
|
|
|
)
|
2021-08-17 11:49:37 +02:00
|
|
|
command = pack_set_param_command(object_id, PDUConfigTable.out_en_2.parameter_address,
|
2020-12-29 11:29:03 +01:00
|
|
|
PDUConfigTable.out_en_2.parameter_size, Channel.on)
|
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
2021-02-06 16:35:53 +01:00
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.read_temperature:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing temperature reading"))
|
2021-09-07 14:51:50 +02:00
|
|
|
command = pack_get_param_command(
|
|
|
|
object_id, TableIds.hk, PDUHkTable.temperature.parameter_address,
|
|
|
|
PDUHkTable.temperature.parameter_size
|
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.read_channel_2_state:
|
2021-09-07 14:51:50 +02:00
|
|
|
tc_queue.appendleft(
|
|
|
|
(QueueCommands.PRINT, "PDU2: Reading output channel 2 state (TCS Heater)")
|
|
|
|
)
|
|
|
|
command = pack_get_param_command(
|
|
|
|
object_id, TableIds.config, PDUConfigTable.out_en_2.parameter_address,
|
|
|
|
PDUConfigTable.out_en_2.parameter_size
|
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.read_cur_lu_lim_0:
|
2021-09-07 14:51:50 +02:00
|
|
|
tc_queue.appendleft(
|
|
|
|
(QueueCommands.PRINT, "PDU2: Reading current limit value of output channel 0 (OBC)")
|
|
|
|
)
|
|
|
|
command = pack_get_param_command(
|
|
|
|
object_id, TableIds.config, PDUConfigTable.cur_lu_lim_0.parameter_address,
|
|
|
|
PDUConfigTable.cur_lu_lim_0.parameter_size
|
|
|
|
)
|
2020-12-29 11:29:03 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.channel_2_off:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Testing setting output channel 2 off"))
|
2021-08-17 11:49:37 +02:00
|
|
|
command = pack_set_param_command(object_id, PDUConfigTable.out_en_2.parameter_address,
|
2020-12-29 11:29:03 +01:00
|
|
|
PDUConfigTable.out_en_2.parameter_size, Channel.off)
|
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
2021-02-06 16:35:53 +01:00
|
|
|
if PDU2TestProcedure.all or PDU2TestProcedure.request_hk_table:
|
2021-02-09 12:35:10 +01:00
|
|
|
tc_queue.appendleft((QueueCommands.PRINT, "PDU2: Requesting housekeeping table"))
|
2021-08-17 11:49:37 +02:00
|
|
|
command = pack_request_full_hk_table_command(object_id)
|
2021-02-06 16:35:53 +01:00
|
|
|
tc_queue.appendleft(command.pack_command_tuple())
|
2021-04-18 16:35:18 +02:00
|
|
|
|
2020-12-29 11:29:03 +01:00
|
|
|
return tc_queue
|