fix overlap
All checks were successful
EIVE/-/pipeline/head This commit looks good

This commit is contained in:
Robin Müller 2023-09-25 17:50:02 +02:00
parent 67c17dc152
commit 22a42108b4
Signed by: muellerr
GPG Key ID: A649FB78196E3849

View File

@ -121,8 +121,9 @@ Event ID (dec); Event ID (hex); Name; Severity; Description; File Path
11603;0x2d53;EXE_FAILURE;LOW;PLOC receive execution failure report P1: Command Id which leads the execution failure report P2: The status field inserted by the MPSoC into the data field;linux/payload/PlocMpsocHandler.h
11604;0x2d54;MPSOC_HANDLER_CRC_FAILURE;LOW;PLOC reply has invalid crc;linux/payload/PlocMpsocHandler.h
11605;0x2d55;MPSOC_HANDLER_SEQUENCE_COUNT_MISMATCH;LOW;Packet sequence count in received space packet does not match expected count P1: Expected sequence count P2: Received sequence count;linux/payload/PlocMpsocHandler.h
11606;0x2d56;SUPV_NOT_ON;LOW;SUPV not on for boot or shutdown process. P1: 0 for OFF transition, 1 for ON transition.;linux/payload/PlocMpsocHandler.h
11607;0x2d57;SUPV_REPLY_TIMEOUT;LOW;No description;linux/payload/PlocMpsocHandler.h
11606;0x2d56;MPSOC_SHUTDOWN_FAILED;HIGH;Supervisor fails to shutdown MPSoC. Requires to power off the PLOC and thus also to shutdown the supervisor.;linux/payload/PlocMpsocHandler.h
11607;0x2d57;SUPV_NOT_ON;LOW;SUPV not on for boot or shutdown process. P1: 0 for OFF transition, 1 for ON transition.;linux/payload/PlocMpsocHandler.h
11608;0x2d58;SUPV_REPLY_TIMEOUT;LOW;No description;linux/payload/PlocMpsocHandler.h
11701;0x2db5;SELF_TEST_I2C_FAILURE;LOW;Get self test result returns I2C failure P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;mission/acs/ImtqHandler.h
11702;0x2db6;SELF_TEST_SPI_FAILURE;LOW;Get self test result returns SPI failure. This concerns the MTM connectivity. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;mission/acs/ImtqHandler.h
11703;0x2db7;SELF_TEST_ADC_FAILURE;LOW;Get self test result returns failure in measurement of current and temperature. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA;mission/acs/ImtqHandler.h

1 Event ID (dec) Event ID (hex) Name Severity Description File Path
121 11603 0x2d53 EXE_FAILURE LOW PLOC receive execution failure report P1: Command Id which leads the execution failure report P2: The status field inserted by the MPSoC into the data field linux/payload/PlocMpsocHandler.h
122 11604 0x2d54 MPSOC_HANDLER_CRC_FAILURE LOW PLOC reply has invalid crc linux/payload/PlocMpsocHandler.h
123 11605 0x2d55 MPSOC_HANDLER_SEQUENCE_COUNT_MISMATCH LOW Packet sequence count in received space packet does not match expected count P1: Expected sequence count P2: Received sequence count linux/payload/PlocMpsocHandler.h
124 11606 0x2d56 SUPV_NOT_ON MPSOC_SHUTDOWN_FAILED LOW HIGH SUPV not on for boot or shutdown process. P1: 0 for OFF transition, 1 for ON transition. Supervisor fails to shutdown MPSoC. Requires to power off the PLOC and thus also to shutdown the supervisor. linux/payload/PlocMpsocHandler.h
125 11607 0x2d57 SUPV_REPLY_TIMEOUT SUPV_NOT_ON LOW No description SUPV not on for boot or shutdown process. P1: 0 for OFF transition, 1 for ON transition. linux/payload/PlocMpsocHandler.h
126 11608 0x2d58 SUPV_REPLY_TIMEOUT LOW No description linux/payload/PlocMpsocHandler.h
127 11701 0x2db5 SELF_TEST_I2C_FAILURE LOW Get self test result returns I2C failure P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA mission/acs/ImtqHandler.h
128 11702 0x2db6 SELF_TEST_SPI_FAILURE LOW Get self test result returns SPI failure. This concerns the MTM connectivity. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA mission/acs/ImtqHandler.h
129 11703 0x2db7 SELF_TEST_ADC_FAILURE LOW Get self test result returns failure in measurement of current and temperature. P1: Indicates on which axis the failure occurred. 0 -> INIT, 1 -> +X, 2 -> -X, 3 -> +Y, 4 -> -Y, 5 -> +Z, 6 -> -Z, 7 -> FINA mission/acs/ImtqHandler.h