Merge remote-tracking branch 'origin/develop' into kranz/master
This commit is contained in:
commit
6db60f9238
@ -345,15 +345,20 @@ def add_time_cmds(cmd_dict: ServiceOpCodeDictT):
|
||||
|
||||
def add_imtq_cmds(cmd_dict: ServiceOpCodeDictT):
|
||||
op_code_dict_srv_imtq = {
|
||||
"0": ("IMTQ Tests All", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"1": ("IMTQ perform pos X self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"2": ("IMTQ perform neg X self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"3": ("IMTQ perform pos Y self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"4": ("IMTQ perform neg Y self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"5": ("IMTQ perform pos Z self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"6": ("IMTQ perform neg Z self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"7": ("IMTQ command dipole", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"8": ("IMTQ get commanded dipole", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"0": ("Mode off", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"1": ("Mode on", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"2": ("Mode normal", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"3": ("IMTQ perform pos X self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"4": ("IMTQ perform neg X self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"5": ("IMTQ perform pos Y self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"6": ("IMTQ perform neg Y self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"7": ("IMTQ perform pos Z self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"8": ("IMTQ perform neg Z self test", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"9": ("IMTQ command dipole", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"10": ("IMTQ get commanded dipole", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"11": ("IMTQ get engineering hk set", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"12": ("IMTQ get calibrated MTM measurement one shot", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
"13": ("IMTQ get raw MTM measurement one shot", {OpCodeDictKeys.TIMEOUT: 2.0}),
|
||||
}
|
||||
service_imtq_tuple = ("IMTQ Device", op_code_dict_srv_imtq)
|
||||
cmd_dict[CustomServiceList.IMTQ.value] = service_imtq_tuple
|
||||
|
@ -9,7 +9,8 @@ from tmtccmd.config.definitions import QueueCommands
|
||||
|
||||
from tmtccmd.tc.packer import TcQueueT
|
||||
from spacepackets.ecss.tc import PusTelecommand
|
||||
from tmtccmd.tc.pus_3_fsfw_hk import make_sid, generate_one_hk_command
|
||||
from tmtccmd.tc.pus_3_fsfw_hk import make_sid, generate_one_diag_command, generate_one_hk_command
|
||||
from tmtccmd.tc.pus_200_fsfw_modes import pack_mode_data, Modes
|
||||
|
||||
|
||||
class ImtqSetIds:
|
||||
@ -48,7 +49,22 @@ def pack_imtq_test_into(
|
||||
)
|
||||
)
|
||||
|
||||
if op_code == "0" or op_code == "1":
|
||||
if op_code == "0":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Set mode off"))
|
||||
command = pack_mode_data(object_id, Modes.OFF, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=9, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if op_code == "1":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Set mode on"))
|
||||
command = pack_mode_data(object_id, Modes.ON, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=10, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if op_code == "2":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Mode Normal"))
|
||||
command = pack_mode_data(object_id, Modes.NORMAL, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=11, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if op_code == "3":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Perform positive x self test"))
|
||||
command = object_id + ImtqActionIds.perform_positive_x_test
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=22, app_data=command)
|
||||
@ -74,7 +90,7 @@ def pack_imtq_test_into(
|
||||
command = generate_one_hk_command(sid, 24)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "2":
|
||||
if op_code == "4":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Perform negative x self test"))
|
||||
command = object_id + ImtqActionIds.perform_negative_x_test
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=25, app_data=command)
|
||||
@ -100,7 +116,7 @@ def pack_imtq_test_into(
|
||||
command = generate_one_hk_command(sid, 27)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "3":
|
||||
if op_code == "5":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Perform positive y self test"))
|
||||
command = object_id + ImtqActionIds.perform_positive_y_test
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=28, app_data=command)
|
||||
@ -126,7 +142,7 @@ def pack_imtq_test_into(
|
||||
command = generate_one_hk_command(sid, 30)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "4":
|
||||
if op_code == "6":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Perform negative y self test"))
|
||||
command = object_id + ImtqActionIds.perform_negative_y_test
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=31, app_data=command)
|
||||
@ -152,7 +168,7 @@ def pack_imtq_test_into(
|
||||
command = generate_one_hk_command(sid, 33)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "5":
|
||||
if op_code == "7":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Perform positive z self test"))
|
||||
command = object_id + ImtqActionIds.perform_positive_z_test
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=34, app_data=command)
|
||||
@ -178,7 +194,7 @@ def pack_imtq_test_into(
|
||||
command = generate_one_hk_command(sid, 36)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "6":
|
||||
if op_code == "8":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Perform negative z self test"))
|
||||
command = object_id + ImtqActionIds.perform_negative_z_test
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=35, app_data=command)
|
||||
@ -204,7 +220,7 @@ def pack_imtq_test_into(
|
||||
command = generate_one_hk_command(sid, 37)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "7":
|
||||
if op_code == "9":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Commanding dipole"))
|
||||
x_dipole = 0
|
||||
y_dipole = 0
|
||||
@ -213,12 +229,33 @@ def pack_imtq_test_into(
|
||||
command = pack_dipole_command(object_id, x_dipole, y_dipole, z_dipole, duration)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "0" or op_code == "8":
|
||||
if op_code == "10":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Get commanded dipole"))
|
||||
command = object_id + ImtqActionIds.get_commanded_dipole
|
||||
command = PusTelecommand(service=8, subservice=128, ssc=21, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "11":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Get engineering hk set"))
|
||||
command = generate_one_diag_command(
|
||||
sid=make_sid(object_id=object_id, set_id=ImtqSetIds.ENG_HK_SET), ssc=0
|
||||
)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "12":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Get calibrated MTM hk set"))
|
||||
command = generate_one_diag_command(
|
||||
sid=make_sid(object_id=object_id, set_id=ImtqSetIds.CAL_MTM_SET), ssc=0
|
||||
)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
if op_code == "13":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "IMTQ: Get raw MTM hk set"))
|
||||
command = generate_one_diag_command(
|
||||
sid=make_sid(object_id=object_id, set_id=ImtqSetIds.RAW_MTM_SET), ssc=0
|
||||
)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
||||
return tc_queue
|
||||
|
||||
|
||||
|
@ -126,7 +126,7 @@ def pack_ploc_supv_commands(
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=10, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
if op_code == "2":
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "Star tracker: Mode Normal"))
|
||||
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Mode Normal"))
|
||||
command = pack_mode_data(object_id, Modes.NORMAL, 0)
|
||||
command = PusTelecommand(service=200, subservice=1, ssc=11, app_data=command)
|
||||
tc_queue.appendleft(command.pack_command_tuple())
|
||||
|
@ -4,6 +4,104 @@ from pus_tm.defs import PrintWrapper
|
||||
from tmtccmd.utility.tmtc_printer import FsfwTmTcPrinter
|
||||
|
||||
|
||||
def handle_eng_set(printer: FsfwTmTcPrinter, hk_data: bytes):
|
||||
pw = PrintWrapper(printer)
|
||||
header_list = [
|
||||
"Digital Voltage [mV]",
|
||||
"Analog Voltage [mV]",
|
||||
"Digital Current [mA]",
|
||||
"Analog Current [mA]",
|
||||
"Coil Current X [mA]",
|
||||
"Coil Current Y [mA]",
|
||||
"Coil Current Z [mA]",
|
||||
"Coil X Temperature [°C]",
|
||||
"Coil Y Temperature [°C]",
|
||||
"Coil Z Temperature [°C]",
|
||||
"Coil Z Temperature [°C]",
|
||||
"MCU Temperature [°C]",
|
||||
]
|
||||
digital_voltage = struct.unpack("!H", hk_data[0:2])[0]
|
||||
analog_voltage = struct.unpack("!H", hk_data[2:4])[0]
|
||||
digital_current = struct.unpack("!f", hk_data[4:8])[0]
|
||||
analog_current = struct.unpack("!f", hk_data[8:12])[0]
|
||||
coil_x_current = struct.unpack("!f", hk_data[12:16])[0]
|
||||
coil_y_current = struct.unpack("!f", hk_data[16:20])[0]
|
||||
coil_z_current = struct.unpack("!f", hk_data[20:24])[0]
|
||||
coil_x_temperature = struct.unpack("!H", hk_data[24:26])[0]
|
||||
coil_y_temperature = struct.unpack("!H", hk_data[26:28])[0]
|
||||
coil_z_temperature = struct.unpack("!H", hk_data[30:32])[0]
|
||||
mcu_temperature = struct.unpack("!H", hk_data[32:34])[0]
|
||||
|
||||
validity_buffer = hk_data[42:]
|
||||
content_list = [
|
||||
digital_voltage,
|
||||
analog_voltage,
|
||||
digital_current,
|
||||
analog_current,
|
||||
coil_x_current,
|
||||
coil_y_current,
|
||||
coil_z_current,
|
||||
coil_x_temperature,
|
||||
coil_y_temperature,
|
||||
coil_z_temperature,
|
||||
mcu_temperature
|
||||
]
|
||||
num_of_vars = len(header_list)
|
||||
pw.dlog(str(header_list))
|
||||
pw.dlog(str(content_list))
|
||||
printer.print_validity_buffer(validity_buffer=validity_buffer, num_vars=num_of_vars)
|
||||
|
||||
|
||||
def handle_calibrated_mtm_measurement(printer: FsfwTmTcPrinter, hk_data: bytes):
|
||||
pw = PrintWrapper(printer)
|
||||
header_list = [
|
||||
"Calibrated MTM X [nT]",
|
||||
"Calibrated MTM Y [nT]",
|
||||
"Calibrated MTM Z [nT]",
|
||||
"Coild actuation status"
|
||||
]
|
||||
mtm_x = struct.unpack("!I", hk_data[0:4])[0]
|
||||
mtm_y = struct.unpack("!I", hk_data[4:8])[0]
|
||||
mtm_z = struct.unpack("!I", hk_data[8:12])[0]
|
||||
coil_actuation_status = hk_data[12]
|
||||
validity_buffer = hk_data[12:]
|
||||
content_list = [
|
||||
mtm_x,
|
||||
mtm_y,
|
||||
mtm_z,
|
||||
coil_actuation_status
|
||||
]
|
||||
num_of_vars = len(header_list)
|
||||
pw.dlog(str(header_list))
|
||||
pw.dlog(str(content_list))
|
||||
printer.print_validity_buffer(validity_buffer=validity_buffer, num_vars=num_of_vars)
|
||||
|
||||
|
||||
def handle_raw_mtm_measurement(printer: FsfwTmTcPrinter, hk_data: bytes):
|
||||
pw = PrintWrapper(printer)
|
||||
header_list = [
|
||||
"Raw MTM X [nT]",
|
||||
"Raw MTM Y [nT]",
|
||||
"Raw MTM Z [nT]",
|
||||
"Coild actuation status"
|
||||
]
|
||||
mtm_x = struct.unpack("!f", hk_data[0:4])[0]
|
||||
mtm_y = struct.unpack("!f", hk_data[4:8])[0]
|
||||
mtm_z = struct.unpack("!f", hk_data[8:12])[0]
|
||||
coil_actuation_status = hk_data[12]
|
||||
validity_buffer = hk_data[12:]
|
||||
content_list = [
|
||||
mtm_x,
|
||||
mtm_y,
|
||||
mtm_z,
|
||||
coil_actuation_status
|
||||
]
|
||||
num_of_vars = len(header_list)
|
||||
pw.dlog(str(header_list))
|
||||
pw.dlog(str(content_list))
|
||||
printer.print_validity_buffer(validity_buffer=validity_buffer, num_vars=num_of_vars)
|
||||
|
||||
|
||||
def handle_self_test_data(printer: FsfwTmTcPrinter, hk_data: bytes):
|
||||
pw = PrintWrapper(printer)
|
||||
header_list = [
|
||||
|
@ -15,7 +15,8 @@ from tmtccmd.logging import get_console_logger
|
||||
from pus_tm.devs.bpx_bat import handle_bpx_hk_data
|
||||
from pus_tm.devs.gps import handle_gps_data
|
||||
from pus_tm.devs.gyros import handle_gyros_hk_data
|
||||
from pus_tm.devs.imtq_mgt import handle_self_test_data
|
||||
from pus_tm.devs.imtq_mgt import handle_self_test_data, handle_eng_set, handle_calibrated_mtm_measurement, \
|
||||
handle_raw_mtm_measurement
|
||||
from pus_tm.devs.pcdu import handle_pdu_data, handle_p60_hk_data, handle_acu_hk_data
|
||||
from pus_tm.devs.syrlinks import handle_syrlinks_hk_data
|
||||
from pus_tc.devs.imtq import ImtqSetIds
|
||||
@ -82,8 +83,14 @@ def handle_regular_hk_print(
|
||||
set_id <= ImtqSetIds.NEGATIVE_Z_TEST
|
||||
):
|
||||
return handle_self_test_data(printer, hk_data)
|
||||
elif set_id == ImtqSetIds.ENG_HK_SET:
|
||||
return handle_eng_set(printer, hk_data)
|
||||
elif set_id == ImtqSetIds.CAL_MTM_SET:
|
||||
return handle_calibrated_mtm_measurement(printer, hk_data)
|
||||
elif set_id == ImtqSetIds.RAW_MTM_SET:
|
||||
return handle_raw_mtm_measurement(printer, hk_data)
|
||||
else:
|
||||
LOGGER.info("Service 3 TM: Syrlinks handler reply with unknown set id")
|
||||
LOGGER.info("Service 3 TM: IMTQ handler reply with unknown set id")
|
||||
if objb == obj_ids.GPS_HANDLER_0_ID or object_id == obj_ids.GPS_HANDLER_1_ID:
|
||||
handle_gps_data(printer=printer, hk_data=hk_data)
|
||||
if objb == obj_ids.BPX_HANDLER_ID:
|
||||
|
Loading…