Merge branch 'mueller/update-ploc-supv-cmds' of https://egit.irs.uni-stuttgart.de/eive/eive-tmtc into mueller/update-ploc-supv-cmds
This commit is contained in:
commit
7dfe92be8c
@ -116,11 +116,6 @@ class SetIds:
|
||||
BOOT_STATUS_REPORT = 103
|
||||
|
||||
|
||||
class SupvHkIds:
|
||||
HK_REPORT = 52
|
||||
BOOT_STATUS_REPORT = 53
|
||||
|
||||
|
||||
class OpCodes:
|
||||
OFF = ["0", "off"]
|
||||
ON = ["1", "on"]
|
||||
@ -129,6 +124,7 @@ class OpCodes:
|
||||
REQUEST_HK = ["4", "req-hk"]
|
||||
START_MPSOC = ["5", "mpsoc-start"]
|
||||
STOP_MPSOC = ["6", "mpsoc-stop"]
|
||||
REQ_BOOT_STATUS_REPORT = ["13", "boot-report"]
|
||||
START_UPDATE = ["42", "start-update"]
|
||||
PERFORM_UPDATE = ["update"]
|
||||
MEM_CHECK = ["mem-check"]
|
||||
@ -141,6 +137,7 @@ class Info(str, enum.Enum):
|
||||
NML = "Switch Normal"
|
||||
HK_TO_OBC = "Request HK from PLOC SUPV"
|
||||
REQUEST_HK = "Request HK set from PLOC Handler"
|
||||
REQ_BOOT_STATUS_REPORT = "Request boot status report"
|
||||
MEM_CHECK = "Memory Check"
|
||||
|
||||
|
||||
@ -161,7 +158,7 @@ def add_ploc_supv_cmds(defs: TmtcDefinitionWrapper):
|
||||
oce.add("10", "PLOC Supervisor: Set time reference")
|
||||
oce.add("11", "PLOC Supervisor: Set boot timeout")
|
||||
oce.add("12", "PLOC Supervisor: Disable Hk")
|
||||
oce.add("13", "PLOC Supervisor: Request boot status report")
|
||||
oce.add(OpCodes.REQ_BOOT_STATUS_REPORT, Info.REQ_BOOT_STATUS_REPORT)
|
||||
oce.add("17", "PLOC Supervisor: Enable latchup alert")
|
||||
oce.add("18", "PLOC Supervisor: Disable latchup alert")
|
||||
oce.add("20", "PLOC Supervisor: Set alert limit")
|
||||
@ -226,7 +223,7 @@ def pack_ploc_supv_commands(p: ServiceProviderParams):
|
||||
sid = make_sid(object_id.as_bytes, SetIds.HK_REPORT)
|
||||
cmd = generate_one_hk_command(sid)
|
||||
q.add_pus_tc(cmd)
|
||||
elif op_code == "5":
|
||||
elif op_code in OpCodes.START_MPSOC:
|
||||
q.add_log_cmd("PLOC Supervisor: Start MPSoC")
|
||||
command = obyt + struct.pack("!I", SupvActionIds.START_MPSOC)
|
||||
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=command))
|
||||
@ -272,12 +269,16 @@ def pack_ploc_supv_commands(p: ServiceProviderParams):
|
||||
q.add_log_cmd("PLOC Supervisor: Disable HK")
|
||||
command = object_id.as_bytes + struct.pack("!I", SupvActionIds.DISABLE_HK)
|
||||
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=command))
|
||||
if op_code == "13":
|
||||
q.add_log_cmd("PLOC Supervisor: Request boot status report")
|
||||
if op_code in OpCodes.REQ_BOOT_STATUS_REPORT:
|
||||
q.add_log_cmd(Info.REQ_BOOT_STATUS_REPORT)
|
||||
command = object_id.as_bytes + struct.pack(
|
||||
"!I", SupvActionIds.GET_BOOT_STATUS_REPORT
|
||||
)
|
||||
q.add_pus_tc(PusTelecommand(service=8, subservice=128, app_data=command))
|
||||
q.add_wait_seconds(2.0)
|
||||
sid = make_sid(object_id.as_bytes, SetIds.BOOT_STATUS_REPORT)
|
||||
req_hk = generate_one_hk_command(sid)
|
||||
q.add_pus_tc(req_hk)
|
||||
if op_code == "17":
|
||||
q.add_log_cmd("PLOC Supervisor: Enable latchup alert")
|
||||
command = pack_lachtup_alert_cmd(object_id.as_bytes, True)
|
||||
@ -722,13 +723,34 @@ def get_event_buffer_path() -> str:
|
||||
|
||||
def handle_supv_hk_data(set_id: int, hk_data: bytes, printer: FsfwTmTcPrinter):
|
||||
pw = PrintWrapper(printer)
|
||||
current_idx = 0
|
||||
if set_id == SetIds.HK_REPORT:
|
||||
# TODO: Implement
|
||||
pass
|
||||
elif set_id == SetIds.BOOT_STATUS_REPORT:
|
||||
# TODO: Implement
|
||||
pass
|
||||
fmt_str = "!BBIIBBBBBB"
|
||||
inc_len = struct.calcsize(fmt_str)
|
||||
(
|
||||
soc_state,
|
||||
power_cycles,
|
||||
boot_after_ms,
|
||||
boot_timeout_ms,
|
||||
active_nvm,
|
||||
bp_0_state,
|
||||
bp_1_state,
|
||||
bp_2_state,
|
||||
boot_state,
|
||||
boot_cycles
|
||||
) = struct.unpack(fmt_str, hk_data[0: 0 + inc_len])
|
||||
current_idx += inc_len
|
||||
pw.dlog(
|
||||
f"SoC state (0:off, 1:booting, 2:update, 3:operating, 4:shutdown, 5:reset): {soc_state}"
|
||||
)
|
||||
pw.dlog(f"Power Cycles {power_cycles}")
|
||||
pw.dlog(f"Boot after {boot_after_ms} ms | Boot timeout {boot_timeout_ms} ms")
|
||||
pw.dlog(f"Active NVM: {active_nvm}")
|
||||
pw.dlog(f"BP0 State {bp_0_state} | BP1 State {bp_1_state} | BP2 State {bp_2_state}")
|
||||
pw.dlog(f"Boot State {boot_state} | Boot Cycles {boot_cycles}")
|
||||
pw.printer.print_validity_buffer(hk_data[current_idx:], 10)
|
||||
else:
|
||||
pw.dlog(f"PLOC SUPV: HK handling not implemented for set ID {set_id}")
|
||||
pw.dlog(f"Raw Data: 0x[{hk_data.hex(sep=',')}]")
|
||||
pass
|
||||
|
Loading…