Merge pull request 'PL PCDU parameter update' (#247) from pl-pcdu-param-update into main
EIVE/-/pipeline/head This commit looks good Details

Reviewed-on: #247
This commit is contained in:
Robin Müller 2023-10-24 11:57:09 +02:00
commit 8f8bcde90e
4 changed files with 157 additions and 28 deletions

View File

@ -10,6 +10,10 @@ list yields a list of all related PRs for each release.
# [unreleased]
## Added
- Added command to update PL PCDU I and V parameter bounds.
# [v5.8.0] 2023-10-11
## Added

View File

@ -67,7 +67,7 @@ from eive_tmtc.config.object_ids import (
from eive_tmtc.tmtc.tcs.tmp1075 import pack_tmp1075_test_into
from eive_tmtc.tmtc.acs.gps import pack_gps_command
from eive_tmtc.tmtc.payload.rad_sensor import pack_rad_sensor_test_into
from eive_tmtc.tmtc.power.plpcdu import pack_pl_pcdu_commands
from eive_tmtc.tmtc.payload.plpcdu import pack_pl_pcdu_commands
from eive_tmtc.tmtc.acs.str_img_helper import pack_str_img_helper_command
from eive_tmtc.pus_tc.system.proc import pack_proc_commands

View File

@ -6,7 +6,7 @@ from eive_tmtc.tmtc.internal_err_reporter import handle_ier_hk_data
from eive_tmtc.tmtc.payload.ploc_mpsoc import handle_ploc_mpsoc_hk_data
from eive_tmtc.tmtc.tcs.rtd import RTD_NAMES, handle_rtd_hk
from eive_tmtc.tmtc.acs.star_tracker import handle_str_hk_data
from eive_tmtc.tmtc.power.plpcdu import handle_plpcdu_hk
from eive_tmtc.tmtc.payload.plpcdu import handle_plpcdu_hk
from eive_tmtc.tmtc.payload.rad_sensor import handle_rad_sensor_data
from eive_tmtc.tmtc.acs.sus import handle_sus_hk
from eive_tmtc.tmtc.payload.ploc_supervisor import handle_supv_hk_data

View File

@ -20,7 +20,8 @@ from tmtccmd.tc.pus_11_tc_sched import (
create_enable_tc_sched_cmd,
create_time_tagged_cmd,
)
from tmtccmd.tc.pus_200_fsfw_mode import pack_mode_data, Mode, Subservice
from tmtccmd.pus.s200_fsfw_mode import Subservice
from tmtccmd.tc.pus_200_fsfw_mode import pack_mode_data, Mode
from tmtccmd.tc.pus_20_fsfw_param import (
create_scalar_double_parameter,
create_load_param_cmd,
@ -35,18 +36,22 @@ _LOGGER = logging.getLogger(__name__)
class OpCode:
SWITCH_HPA_ON_PROC = ["0", "proc_hpa"]
SWITCH_ON = ["2", "on"]
SWITCH_OFF = ["3", "off"]
NORMAL_SSR = ["4", "nml_ssr"]
NORMAL_DRO = ["5", "nml_dro"]
NORMAL_X8 = ["6", "nml_x8"]
NORMAL_TX = ["7", "nml_tx"]
NORMAL_MPA = ["8", "nml_mpa"]
NORMAL_HPA = ["9", "nml_hpa"]
SWITCH_ON = "on"
SWITCH_OFF = "off"
NORMAL_SSR = "nml_ssr"
NORMAL_DRO = "nml_dro"
NORMAL_X8 = "nml_x8"
NORMAL_TX = "nml_tx"
NORMAL_MPA = "nml_mpa"
NORMAL_HPA = "nml_hpa"
ENABLE_HK = ["enable_hk"]
DISABLE_HK = ["disable_hk"]
REQ_OS_HK = ["hk_os"]
ENABLE_HK = "enable_hk"
DISABLE_HK = "disable_hk"
REQ_OS_HK = "hk_os"
UPDATE_I_UPPER_LIMIT = "update_i_upper_limit"
UPDATE_V_LOWER_LIMIT = "update_v_lower_limit"
UPDATE_V_UPPER_LIMIT = "update_v_upper_limit"
INJECT_SSR_TO_DRO_FAILURE = ["10", "inject_ssr_dro_fault"]
INJECT_DRO_TO_X8_FAILURE = ["11", "inject_dro_x8_fault"]
@ -70,6 +75,9 @@ class Info:
SWITCH_HPA_ON_PROC = "Switch HPA on procedure"
ENABLE_HK = "Enable HK"
DISABLE_HK = "Disable HK"
UPDATE_I_UPPER_LIMIT = "Update upper current parameter"
UPDATE_V_LOWER_LIMIT = "Update lower voltage parameter"
UPDATE_V_UPPER_LIMIT = "Update upper voltage parameter"
class SetId(enum.IntEnum):
@ -119,7 +127,7 @@ class SubmodeForNormalMode(enum.IntEnum):
)
class ParamIds(enum.IntEnum):
class ParamId(enum.IntEnum):
NEG_V_LOWER_BOUND = 0
NEG_V_UPPER_BOUND = 1
@ -157,6 +165,15 @@ class ParamIds(enum.IntEnum):
INJECT_ALL_ON_FAILURE = 35
class DevSelect(enum.IntEnum):
SSR_NEG_V = 0
DRO = 1
X8 = 2
TX = 3
MPA = 4
HPA = 5
@tmtc_definitions_provider
def add_pl_pcdu_cmds(defs: TmtcDefinitionWrapper):
oce = OpCodeEntry()
@ -171,6 +188,9 @@ def add_pl_pcdu_cmds(defs: TmtcDefinitionWrapper):
oce.add(keys=OpCode.NORMAL_HPA, info=Info.NORMAL_HPA)
oce.add(keys=OpCode.REQ_OS_HK, info=Info.REQ_OS_HK)
oce.add(keys=OpCode.ENABLE_HK, info=Info.ENABLE_HK)
oce.add(keys=OpCode.UPDATE_V_LOWER_LIMIT, info=Info.UPDATE_V_LOWER_LIMIT)
oce.add(keys=OpCode.UPDATE_V_UPPER_LIMIT, info=Info.UPDATE_V_UPPER_LIMIT)
oce.add(keys=OpCode.UPDATE_I_UPPER_LIMIT, info=Info.UPDATE_I_UPPER_LIMIT)
oce.add(
keys=OpCode.INJECT_SSR_TO_DRO_FAILURE,
info="Inject failure SSR to DRO transition",
@ -198,9 +218,9 @@ def add_pl_pcdu_cmds(defs: TmtcDefinitionWrapper):
def pack_pl_pcdu_commands( # noqa C901: Complexity is okay here.
q: DefaultPusQueueHelper, op_code: str
): # noqa C901: Complexity is okay here.
if op_code in OpCode.SWITCH_ON:
if op_code == OpCode.SWITCH_ON:
pack_pl_pcdu_mode_cmd(q=q, info=Info.SWITCH_ON, mode=Mode.ON, submode=0)
if op_code in OpCode.SWITCH_OFF:
if op_code == OpCode.SWITCH_OFF:
pack_pl_pcdu_mode_cmd(q=q, info=Info.SWITCH_OFF, mode=Mode.OFF, submode=0)
if op_code in OpCode.ENABLE_HK:
interval = float(
@ -212,13 +232,13 @@ def pack_pl_pcdu_commands( # noqa C901: Complexity is okay here.
q.add_log_cmd(f"Enable PL PCDU HK with interval of {interval} seconds")
for cmd in cmds:
q.add_pus_tc(cmd)
if op_code in OpCode.DISABLE_HK:
if op_code == OpCode.DISABLE_HK:
cmd = disable_periodic_hk_command(
diag=True, sid=make_sid(PL_PCDU_ID, SetId.ADC)
)
q.add_log_cmd("Disabling PL PCDU HK")
q.add_pus_tc(cmd)
if op_code in OpCode.NORMAL_SSR:
if op_code == OpCode.NORMAL_SSR:
pack_pl_pcdu_mode_cmd(
q=q,
info=Info.NORMAL_SSR,
@ -227,54 +247,90 @@ def pack_pl_pcdu_commands( # noqa C901: Complexity is okay here.
NormalSubmodesMask.SOLID_STATE_RELAYS_ADC_ON
),
)
if op_code in OpCode.NORMAL_DRO:
if op_code == OpCode.NORMAL_DRO:
pack_pl_pcdu_mode_cmd(
q=q,
info=Info.NORMAL_DRO,
mode=Mode.NORMAL,
submode=submode_mask_to_submode(NormalSubmodesMask.DRO_ON),
)
if op_code in OpCode.NORMAL_X8:
if op_code == OpCode.NORMAL_X8:
pack_pl_pcdu_mode_cmd(
q=q,
info=Info.NORMAL_X8,
mode=Mode.NORMAL,
submode=submode_mask_to_submode(NormalSubmodesMask.X8_ON),
)
if op_code in OpCode.NORMAL_TX:
if op_code == OpCode.NORMAL_TX:
pack_pl_pcdu_mode_cmd(
q=q,
info=Info.NORMAL_TX,
mode=Mode.NORMAL,
submode=submode_mask_to_submode(NormalSubmodesMask.TX_ON),
)
if op_code in OpCode.NORMAL_MPA:
if op_code == OpCode.NORMAL_MPA:
pack_pl_pcdu_mode_cmd(
q=q,
info=Info.NORMAL_MPA,
mode=Mode.NORMAL,
submode=submode_mask_to_submode(NormalSubmodesMask.MPA_ON),
)
if op_code in OpCode.NORMAL_HPA:
if op_code == OpCode.NORMAL_HPA:
pack_pl_pcdu_mode_cmd(
q=q,
info=Info.NORMAL_HPA,
mode=Mode.NORMAL,
submode=submode_mask_to_submode(NormalSubmodesMask.HPA_ON),
)
if op_code in OpCode.REQ_OS_HK:
if op_code == OpCode.REQ_OS_HK:
q.add_log_cmd(f"PL PCDU: {Info.REQ_OS_HK}")
q.add_pus_tc(
generate_one_diag_command(
sid=make_sid(object_id=PL_PCDU_ID, set_id=SetId.ADC)
)
)
if op_code in OpCode.SWITCH_HPA_ON_PROC:
if op_code == OpCode.UPDATE_I_UPPER_LIMIT:
q.add_log_cmd(Info.UPDATE_I_UPPER_LIMIT)
print("Select device to update lower current limit for: ")
param_id = dev_select_to_upper_i_update_param_id(dev_select_prompt(True))
new_param_value = float(
input("Please specify new parameter value as a double: ")
)
q.add_pus_tc(
create_load_param_cmd(
create_scalar_double_parameter(PL_PCDU_ID, 0, param_id, new_param_value)
)
)
if op_code == OpCode.UPDATE_V_LOWER_LIMIT:
q.add_log_cmd(Info.UPDATE_V_LOWER_LIMIT)
print("Select device to update lower voltage limit for: ")
param_id = dev_select_to_lower_u_update_param_id(dev_select_prompt(False))
new_param_value = float(
input("Please specify new parameter value as a double: ")
)
q.add_pus_tc(
create_load_param_cmd(
create_scalar_double_parameter(PL_PCDU_ID, 0, param_id, new_param_value)
)
)
if op_code == OpCode.UPDATE_V_UPPER_LIMIT:
q.add_log_cmd(Info.UPDATE_V_UPPER_LIMIT)
print("Select device to update upper voltage limit for: ")
param_id = dev_select_to_upper_u_update_param_id(dev_select_prompt(False))
new_param_value = float(
input("Please specify new parameter value as a double: ")
)
q.add_pus_tc(
create_load_param_cmd(
create_scalar_double_parameter(PL_PCDU_ID, 0, param_id, new_param_value)
)
)
if op_code == OpCode.SWITCH_HPA_ON_PROC:
hpa_on_procedure(q)
if op_code in OpCode.INJECT_ALL_ON_FAILURE:
if op_code == OpCode.INJECT_ALL_ON_FAILURE:
pack_failure_injection_cmd(
q=q,
param_id=ParamIds.INJECT_ALL_ON_FAILURE,
param_id=ParamId.INJECT_ALL_ON_FAILURE,
print_str="All On",
)
@ -510,3 +566,72 @@ def handle_plpcdu_hk(pw: PrintWrapper, set_id: int, hk_data: bytes):
FsfwTmTcPrinter.get_validity_buffer(
validity_buffer=hk_data[current_idx:], num_vars=3
)
def dev_select_prompt(skip_ssr: bool) -> DevSelect:
while True:
for dev in DevSelect:
if skip_ssr and dev == DevSelect.SSR_NEG_V:
continue
print(f"{dev}: {dev.name}")
dev_select = int(input("Select device by index: "))
try:
return DevSelect(dev_select)
except IndexError:
_LOGGER.warn("Invalid paramter index, try again.")
continue
def dev_select_to_upper_i_update_param_id(dev_select: DevSelect) -> ParamId:
param_id = None
if dev_select == DevSelect.DRO:
param_id = ParamId.DRO_I_UPPER_BOUND
elif dev_select == DevSelect.X8:
param_id = ParamId.X8_I_UPPER_BOUND
elif dev_select == DevSelect.TX:
param_id = ParamId.TX_I_UPPER_BOUND
elif dev_select == DevSelect.MPA:
param_id = ParamId.MPA_I_UPPER_BOUND
elif dev_select == DevSelect.HPA:
param_id = ParamId.HPA_I_UPPER_BOUND
if param_id is None:
raise ValueError("invalid parameter ID")
return param_id
def dev_select_to_lower_u_update_param_id(dev_select: DevSelect) -> ParamId:
param_id = None
if dev_select == DevSelect.SSR_NEG_V:
param_id = ParamId.NEG_V_LOWER_BOUND
if dev_select == DevSelect.DRO:
param_id = ParamId.DRO_U_LOWER_BOUND
elif dev_select == DevSelect.X8:
param_id = ParamId.X8_U_LOWER_BOUND
elif dev_select == DevSelect.TX:
param_id = ParamId.TX_U_LOWER_BOUND
elif dev_select == DevSelect.MPA:
param_id = ParamId.MPA_U_LOWER_BOUND
elif dev_select == DevSelect.HPA:
param_id = ParamId.HPA_U_LOWER_BOUND
if param_id is None:
raise ValueError("invalid parameter ID")
return param_id
def dev_select_to_upper_u_update_param_id(dev_select: DevSelect) -> ParamId:
param_id = None
if dev_select == DevSelect.SSR_NEG_V:
param_id = ParamId.NEG_V_UPPER_BOUND
if dev_select == DevSelect.DRO:
param_id = ParamId.DRO_U_UPPER_BOUND
elif dev_select == DevSelect.X8:
param_id = ParamId.X8_U_UPPER_BOUND
elif dev_select == DevSelect.TX:
param_id = ParamId.TX_U_UPPER_BOUND
elif dev_select == DevSelect.MPA:
param_id = ParamId.MPA_U_UPPER_BOUND
elif dev_select == DevSelect.HPA:
param_id = ParamId.HPA_U_UPPER_BOUND
if param_id is None:
raise ValueError("invalid parameter ID")
return param_id