Compare commits

...

11 Commits

Author SHA1 Message Date
3305e1d489 Merge pull request 'Update TMTC and linter script' (#15) from mueller/master into develop
Reviewed-on: #15
2021-08-09 14:19:43 +02:00
7c598f26a8 instructions to run linter 2021-08-09 11:45:01 +02:00
5ea6903881 updated linter python script 2021-08-09 11:38:37 +02:00
6824e7d8c7 made CLI and GUI executable 2021-08-09 11:31:08 +02:00
ca63149a67 Merge remote-tracking branch 'origin/develop' into mueller/master 2021-08-09 11:29:55 +02:00
f00cd8f6bd Merge pull request 'meier/plocSupervisor' (#14) from meier/plocSupervisor into develop
Reviewed-on: #14
2021-08-09 11:28:39 +02:00
Jakob.Meier
547b4b2137 fixed conflicts 2021-08-08 15:20:28 +02:00
Jakob.Meier
e7d8199e67 ploc updater commands 2021-08-08 15:02:29 +02:00
Jakob.Meier
98a1d0f856 supervisor CAN loopback test 2021-08-08 10:58:14 +02:00
Jakob.Meier
36ae6a233c ploc udpater test 2021-08-07 14:34:26 +02:00
Jakob.Meier
4aebf4c0d9 debug tcs added 2021-08-02 15:28:34 +02:00
10 changed files with 219 additions and 16 deletions

View File

@@ -1,5 +1,25 @@
# TMTC Commander EIVE
# Run Linter
Can be used to quickly check validity of script. Install `flake8` first
```sh
python3 -m pip install flake8
```
or on Windows
```sh
py -m pip install flake8
```
and then run the `lint.py` script
```sh
./lint.py
```
# Set up virtual environment
## Linux

View File

@@ -29,4 +29,5 @@ class CustomServiceList(enum.Enum):
REACTION_WHEEL_4 = "reaction_wheel_4"
RAD_SENSOR = "rad_sensor"
PLOC_SUPV = "ploc_supv"
PLOC_UPDATER = "ploc_updater"
CORE = 'core'

View File

@@ -131,9 +131,24 @@ class EiveHookObject(TmTcHookBase):
"32": ("PLOC Supervisor: MRAM Dump", {OpCodeDictKeys.TIMEOUT: 2.0}),
"33": ("PLOC Supervisor: Print CPU stats", {OpCodeDictKeys.TIMEOUT: 2.0}),
"34": ("PLOC Supervisor: Set debug verbosity", {OpCodeDictKeys.TIMEOUT: 2.0}),
"35": ("PLOC Supervisor: Set GPIO", {OpCodeDictKeys.TIMEOUT: 2.0}),
"36": ("PLOC Supervisor: Read GPIO", {OpCodeDictKeys.TIMEOUT: 2.0}),
"37": ("PLOC Supervisor: Restart supervisor", {OpCodeDictKeys.TIMEOUT: 2.0}),
"38": ("PLOC Supervisor: Factory reset clear all", {OpCodeDictKeys.TIMEOUT: 2.0}),
"39": ("PLOC Supervisor: Factory reset clear mirror entries", {OpCodeDictKeys.TIMEOUT: 2.0}),
"40": ("PLOC Supervisor: Factory reset clear circular entries", {OpCodeDictKeys.TIMEOUT: 2.0}),
"41": ("PLOC Supervisor: CAN loopback test", {OpCodeDictKeys.TIMEOUT: 2.0}),
}
service_ploc_supv_tuple = ("PLOC Supervisor", op_code_dict_srv_ploc_supv)
op_code_dict_srv_ploc_updater = {
"0": ("Ploc Updater: Update partion A on NVM0", {OpCodeDictKeys.TIMEOUT: 2.0}),
"1": ("Ploc Updater: Update partion B on NVM0", {OpCodeDictKeys.TIMEOUT: 2.0}),
"2": ("Ploc Updater: Update partion A on NVM1", {OpCodeDictKeys.TIMEOUT: 2.0}),
"3": ("Ploc Updater: Update partion B on NVM1", {OpCodeDictKeys.TIMEOUT: 2.0}),
}
service_ploc_updater_tuple = ("Ploc Updater", op_code_dict_srv_ploc_updater)
service_op_code_dict[CustomServiceList.P60DOCK.value] = service_p60_tuple
service_op_code_dict[CustomServiceList.PDU1.value] = service_pdu1_tuple
service_op_code_dict[CustomServiceList.PDU1.value] = service_pdu2_tuple
@@ -145,6 +160,7 @@ class EiveHookObject(TmTcHookBase):
service_op_code_dict[CustomServiceList.REACTION_WHEEL_4.value] = service_rw_tuple
service_op_code_dict[CustomServiceList.RAD_SENSOR.value] = service_rad_sensor_tuple
service_op_code_dict[CustomServiceList.PLOC_SUPV.value] = service_ploc_supv_tuple
service_op_code_dict[CustomServiceList.PLOC_UPDATER.value] = service_ploc_updater_tuple
return service_op_code_dict
def get_json_config_file_path(self) -> str:

View File

@@ -26,6 +26,7 @@ RW4_ID = bytes([0x44, 0x12, 0x00, 0x4])
START_TRACKER_ID = bytes([0x44, 0x13, 0x00, 0x1])
RAD_SENSOR_ID = bytes([0x44, 0x32, 0x00, 0xA5])
PLOC_SUPV_ID = bytes([0x44, 0x33, 0x00, 0x16])
PLOC_UPDATER_ID = bytes([0x44, 0x33, 0x00, 0x00])
CORE_CONTROLLER_ID = bytes([0x43, 0x00, 0x00, 0x03])

13
lint.py
View File

@@ -4,11 +4,20 @@ import sys
def main():
status = os.system("flake8 . --count --select=E9,F63,F7,F82 --show-source --statistics")
# Ignore folder created by venv
exclude_dirs_flag = '--exclude bin,lib'
additional_flags_both_steps = '--count --statistics'
additional_flags_first_step = '--select=E9,F63,F7,F82 --show-source'
flake8_first_step_cmd = \
f'flake8 . {additional_flags_both_steps} {additional_flags_first_step} {exclude_dirs_flag}'
status = os.system(flake8_first_step_cmd)
if os.WEXITSTATUS(status) != 0:
print("Flake8 linter errors")
sys.exit(0)
os.system("flake8 . --count --exit-zero --max-complexity=10 --max-line-length=127 --statistics")
flake8_second_step_cmd = \
f'flake8 . {additional_flags_both_steps} --exit-zero --max-complexity=10 ' \
f'--max-line-length=127 {exclude_dirs_flag}'
os.system(flake8_second_step_cmd)
if __name__ == "__main__":

View File

@@ -12,6 +12,9 @@ from tmtccmd.config.definitions import QueueCommands
from tmtccmd.tc.packer import TcQueueT
from tmtccmd.ecss.tc import PusTelecommand
from tmtccmd.utility.logger import get_console_logger
LOGGER = get_console_logger()
latchup_id_dict = {
"0": "0.85V",
@@ -60,9 +63,11 @@ class SupvActionIds:
SET_GPIO = 34
READ_GPIO = 35
RESTART_SUPERVISOR = 36
FACTORY_RESET = 37
FACTORY_RESET_CLEAR_ALL = 37
REQUEST_LOGGING_DATA = 38
UPDATE_IMAGE_DATA = 39
FACTORY_RESET_CLEAR_MIRROR = 40
FACTORY_RESET_CLEAR_CIRCULAR = 41
class SupvHkIds:
@@ -242,6 +247,41 @@ def pack_ploc_supv_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code:
command = pack_set_debug_verbosity_cmd(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=49, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "35":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Set GPIO command"))
command = pack_set_gpio_cmd(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=50, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "36":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Read GPIO command"))
command = pack_read_gpio_cmd(object_id)
command = PusTelecommand(service=8, subservice=128, ssc=51, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "37":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Restart supervisor"))
command = command = object_id + struct.pack('!I', SupvActionIds.RESTART_SUPERVISOR)
command = PusTelecommand(service=8, subservice=128, ssc=52, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "38":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Factory reset clear all"))
command = command = object_id + struct.pack('!I', SupvActionIds.FACTORY_RESET_CLEAR_ALL)
command = PusTelecommand(service=8, subservice=128, ssc=53, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "39":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Factory reset clear mirror entries"))
command = command = object_id + struct.pack('!I', SupvActionIds.FACTORY_RESET_CLEAR_MIRROR)
command = PusTelecommand(service=8, subservice=128, ssc=54, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "40":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Factory reset clear circular entries"))
command = command = object_id + struct.pack('!I', SupvActionIds.FACTORY_RESET_CLEAR_CIRCULAR)
command = PusTelecommand(service=8, subservice=128, ssc=55, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
elif op_code == "41":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: CAN loopback test"))
command = command = object_id + struct.pack('!I', SupvActionIds.CAN_LOOPBACK_TEST)
command = PusTelecommand(service=8, subservice=128, ssc=56, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
return tc_queue
@@ -488,17 +528,56 @@ def pack_print_cpu_stats_cmd(object_id: bytearray) -> bytearray:
def pack_set_debug_verbosity_cmd(object_id: bytearray) -> bytearray:
command = bytearray()
print("Specify debug verbosity")
verbosity_options_dict = {
0: "None",
1: "Error",
2: "Warn",
3: "Info",
}
print("{:<6} | {}".format('Key', 'Description'))
for entry in verbosity_options_dict.items():
print("{:<6} | {}".format(entry[0], entry[1]))
verbosity = int(input("Specify verbosity key: "))
verbosity = get_debug_verbosity()
command = object_id + struct.pack('!I', SupvActionIds.SET_DBG_VERBOSITY)
command = command + struct.pack('!B', verbosity)
return command
return command
def get_debug_verbosity() -> int:
tries = 0
while tries < 3:
try:
print("Debug verbosity options")
verbosity_options_dict = {
0: "None",
1: "Error",
2: "Warn",
3: "Info",
}
print("{:<6} | {}".format('Key', 'Description'))
for entry in verbosity_options_dict.items():
print("{:<6} | {}".format(entry[0], entry[1]))
verbosity = int(input("Specify verbosity key: "))
if verbosity > len(verbosity_options_dict) - 1:
raise ValueError
return verbosity
except ValueError:
LOGGER.warning("Invalid verbosity key specified")
tries = tries + 1
LOGGER.error("get_debug_verbosity: Exceeded max tries to input verbosity key")
quit()
def pack_set_gpio_cmd(object_id: bytearray) -> bytearray:
port = int(input("Specify port: "))
pin = int(input("Specify pin: "))
val = int(input("Specify val: "))
command = bytearray()
command = object_id + struct.pack('!I', SupvActionIds.SET_GPIO)
command = command + struct.pack('!B', port)
command = command + struct.pack('!B', pin)
command = command + struct.pack('!B', val)
return command
def pack_read_gpio_cmd(object_id: bytearray) -> bytearray:
port = int(input("Specify port: "))
pin = int(input("Specify pin: "))
command = bytearray()
command = object_id + struct.pack('!I', SupvActionIds.READ_GPIO)
command = command + struct.pack('!B', port)
command = command + struct.pack('!B', pin)
return command

73
pus_tc/ploc_upater.py Normal file
View File

@@ -0,0 +1,73 @@
# -*- coding: utf-8 -*-
"""
@file ploc_supervisor.py
@brief Tests for commanding the supervisor of the PLOC.
The supervisor is programmed by Thales.
@author J. Meier
@date 10.07.2021
"""
import struct
from tmtccmd.config.definitions import QueueCommands
from tmtccmd.tc.packer import TcQueueT
from tmtccmd.ecss.tc import PusTelecommand
from tmtccmd.utility.logger import get_console_logger
LOGGER = get_console_logger()
latchup_id_dict = {
"0": "0.85V",
"1": "1.8V",
"2": "MISC",
"3": "3.3V",
"4": "NVM_4XO",
"5": "MISSION",
"6": "SAFECOTS"
}
class UpdaterActionIds:
UPDATE_NVM0_A = 0
UPDATE_NVM0_B = 1
UPDATE_NVM1_A = 2
UPDATE_NVM1_B = 3
class ImagePathDefs:
imageNvm0A = "/mnt/sd0/ploc/updateNvm0A.bin"
imageNvm0B = "/mnt/sd0/ploc/updateNvm0B.bin"
imageNvm1A = "/mnt/sd0/ploc/updateNvm1A.bin"
imageNvm1B = "/mnt/sd0/ploc/updateNvm1B.bin"
def pack_ploc_updater_test_into(object_id: bytearray, tc_queue: TcQueueT, op_code: str) -> TcQueueT:
tc_queue.appendleft(
(QueueCommands.PRINT,
"Testing PLOC updater with object id: 0x" + object_id.hex())
)
if op_code == "0":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Update partition A on NVM0"))
command = object_id + struct.pack('!I', UpdaterActionIds.UPDATE_NVM0_A) + \
bytearray(ImagePathDefs.imageNvm0A, 'utf-8')
command = PusTelecommand(service=8, subservice=128, ssc=30, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "1":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Update partition B on NVM0"))
command = object_id + struct.pack('!I', UpdaterActionIds.UPDATE_NVM0_B) + \
bytearray(ImagePathDefs.imageNvm0B, 'utf-8')
command = PusTelecommand(service=8, subservice=128, ssc=31, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "2":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Update partition A on NVM1"))
command = object_id + struct.pack('!I', UpdaterActionIds.UPDATE_NVM1_A) + \
bytearray(ImagePathDefs.imageNvm1A, 'utf-8')
command = PusTelecommand(service=8, subservice=128, ssc=32, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())
if op_code == "3":
tc_queue.appendleft((QueueCommands.PRINT, "PLOC Supervisor: Update partition B on NVM1"))
command = object_id + struct.pack('!I', UpdaterActionIds.UPDATE_NVM1_B) + \
bytearray(ImagePathDefs.imageNvm1B, 'utf-8')
command = PusTelecommand(service=8, subservice=128, ssc=33, app_data=command)
tc_queue.appendleft(command.pack_command_tuple())

View File

@@ -26,11 +26,12 @@ from pus_tc.ploc_supervisor import pack_ploc_supv_test_into
from pus_tc.heater import pack_heater_test_into
from pus_tc.reaction_wheels import pack_single_rw_test_into
from pus_tc.rad_sensor import pack_rad_sensor_test_into
from pus_tc.ploc_upater import pack_ploc_updater_test_into
from pus_tc.core import pack_core_commands
from config.definitions import CustomServiceList
from config.object_ids import P60_DOCK_HANDLER, PDU_1_HANDLER_ID, PDU_2_HANDLER_ID, ACU_HANDLER_ID, \
TMP_1075_1_HANDLER_ID, TMP_1075_2_HANDLER_ID, HEATER_ID, IMTQ_HANDLER_ID, PLOC_MPSOC_ID, RW1_ID, RW2_ID, RW3_ID, RW4_ID, \
RAD_SENSOR_ID, PLOC_SUPV_ID
RAD_SENSOR_ID, PLOC_SUPV_ID, PLOC_UPDATER_ID
LOGGER = get_console_logger()
@@ -94,6 +95,9 @@ def pack_service_queue_user(service: Union[str, int], op_code: str, service_queu
if service == CustomServiceList.PLOC_SUPV.value:
object_id = PLOC_SUPV_ID
return pack_ploc_supv_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
if service == CustomServiceList.PLOC_UPDATER.value:
object_id = PLOC_UPDATER_ID
return pack_ploc_updater_test_into(object_id=object_id, tc_queue=service_queue, op_code=op_code)
if service == CustomServiceList.CORE.value:
return pack_core_commands(tc_queue=service_queue, op_code=op_code)
LOGGER.warning("Invalid Service !")

0
tmtc_client_cli.py Normal file → Executable file
View File

0
tmtc_client_gui.py Normal file → Executable file
View File