changelog
All checks were successful
EIVE/eive-obsw/pipeline/pr-main This commit looks good

This commit is contained in:
Marius Eggert 2023-10-30 08:52:18 +01:00
parent ad6fa66daf
commit a2090448ff
2 changed files with 8 additions and 7 deletions

View File

@ -57,6 +57,7 @@ will consitute of a breaking change warranting a new major release:
- SUS FDIR should now trigger less events. The finish event is now only triggered once the
SUS has been working properly for a minute again. It will then display the number of periods
during which the SUS was not working as well as the maximum amount of invalid messages.
- Updated battery internal resistance to new value
# [v7.1.0] 2023-10-11

View File

@ -53,13 +53,13 @@ class PowerController : public ExtendedControllerBase, public ReceivesParameterM
ReturnValue_t calculateCoulombCounterChargeUpperThreshold();
// Parameters
float batteryInternalResistance = 70.0 / 2.0 / 1000.0 * 1.94; // [Ohm]
float batteryMaximumCapacity = 2.6 * 2; // [Ah]
float coulombCounterVoltageUpperThreshold = 16.2; // [V]
double maxAllowedTimeDiff = 1.5; // [s]
float payloadOpLimitOn = 0.90; // [%]
float payloadOpLimitLow = 0.75; // [%]
float higherModesLimit = 0.6; // [%]
float batteryInternalResistance = 0.06798200367; // [Ohm]
float batteryMaximumCapacity = 2.6 * 2; // [Ah]
float coulombCounterVoltageUpperThreshold = 16.2; // [V]
double maxAllowedTimeDiff = 1.5; // [s]
float payloadOpLimitOn = 0.90; // [%]
float payloadOpLimitLow = 0.75; // [%]
float higherModesLimit = 0.6; // [%]
// OCV Look-up-Table {[Ah],[V]}
static constexpr uint8_t LOOK_UP_TABLE_MAX_IDX = 99;