2022-02-03 15:03:02 +01:00
|
|
|
from config.object_ids import BPX_HANDLER_ID
|
2022-08-08 16:32:18 +02:00
|
|
|
from tmtccmd.tc import DefaultPusQueueHelper
|
2022-05-05 16:15:53 +02:00
|
|
|
from tmtccmd.tc.pus_8_funccmd import generate_action_command
|
|
|
|
from tmtccmd.tc.pus_3_fsfw_hk import generate_one_hk_command, make_sid
|
2022-02-03 15:03:02 +01:00
|
|
|
|
|
|
|
|
|
|
|
class BpxSetIds:
|
|
|
|
GET_HK_SET = 0
|
|
|
|
GET_CFG_SET = 5
|
|
|
|
|
|
|
|
|
|
|
|
class BpxActionIds:
|
|
|
|
REBOOT = 2
|
|
|
|
RESET_COUNTERS = 3
|
|
|
|
SET_CFG = 4
|
|
|
|
GET_CFG = 5
|
|
|
|
|
|
|
|
|
2022-02-03 16:02:55 +01:00
|
|
|
class BpxOpCodes:
|
|
|
|
HK = ["0", "hk"]
|
|
|
|
RST_BOOT_CNT = ["1", "rst_boot_cnt"]
|
|
|
|
REQUEST_CFG = ["2", "cfg"]
|
|
|
|
REQUEST_CFG_HK = ["3", "cfg_hk"]
|
|
|
|
REBOOT = ["4", "reboot"]
|
|
|
|
|
|
|
|
|
2022-08-08 16:32:18 +02:00
|
|
|
def pack_bpx_commands(q: DefaultPusQueueHelper, op_code: str):
|
2022-02-03 16:02:55 +01:00
|
|
|
if op_code in BpxOpCodes.HK:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("Requesting BPX battery HK set")
|
2022-02-03 15:03:02 +01:00
|
|
|
sid = make_sid(object_id=BPX_HANDLER_ID, set_id=BpxSetIds.GET_HK_SET)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(generate_one_hk_command(sid=sid))
|
2022-02-03 16:02:55 +01:00
|
|
|
if op_code in BpxOpCodes.RST_BOOT_CNT:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("Resetting reboot counters")
|
|
|
|
q.add_pus_tc(
|
|
|
|
generate_action_command(
|
|
|
|
object_id=BPX_HANDLER_ID, action_id=BpxActionIds.RESET_COUNTERS
|
|
|
|
)
|
2022-02-03 15:03:02 +01:00
|
|
|
)
|
2022-02-03 16:02:55 +01:00
|
|
|
if op_code in BpxOpCodes.REQUEST_CFG:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("Requesting configuration struct")
|
|
|
|
q.add_pus_tc(
|
|
|
|
generate_action_command(
|
|
|
|
object_id=BPX_HANDLER_ID, action_id=BpxActionIds.GET_CFG
|
|
|
|
)
|
2022-02-03 15:30:58 +01:00
|
|
|
)
|
2022-02-03 16:02:55 +01:00
|
|
|
if op_code in BpxOpCodes.REQUEST_CFG_HK:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("Requesting configuration struct HK")
|
2022-02-03 15:30:58 +01:00
|
|
|
sid = make_sid(object_id=BPX_HANDLER_ID, set_id=BpxSetIds.GET_CFG_SET)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(generate_one_hk_command(sid=sid))
|
2022-02-03 16:02:55 +01:00
|
|
|
if op_code in BpxOpCodes.REBOOT:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("Rebooting BPX battery")
|
|
|
|
q.add_pus_tc(
|
|
|
|
generate_action_command(
|
|
|
|
object_id=BPX_HANDLER_ID, action_id=BpxActionIds.REBOOT
|
|
|
|
)
|
2022-02-03 16:02:55 +01:00
|
|
|
)
|