2021-01-10 11:42:06 +01:00
|
|
|
# -*- coding: utf-8 -*-
|
|
|
|
"""
|
2021-04-11 11:08:52 +02:00
|
|
|
@file tmp1075.py
|
2021-01-10 11:42:06 +01:00
|
|
|
@brief TMP1075 tests
|
|
|
|
@author J. Meier
|
|
|
|
@date 06.01.2021
|
|
|
|
"""
|
2023-01-16 17:11:20 +01:00
|
|
|
import enum
|
2023-06-18 13:30:45 +02:00
|
|
|
import struct
|
2023-01-16 17:11:20 +01:00
|
|
|
|
2023-11-28 17:41:46 +01:00
|
|
|
from tmtccmd.config import CmdTreeNode
|
|
|
|
|
2023-02-06 14:44:37 +01:00
|
|
|
from eive_tmtc.config.definitions import CustomServiceList
|
2023-06-18 13:30:45 +02:00
|
|
|
from eive_tmtc.pus_tm.defs import PrintWrapper
|
2021-10-01 10:55:56 +02:00
|
|
|
from spacepackets.ecss.tc import PusTelecommand
|
2023-02-06 14:44:37 +01:00
|
|
|
from tmtccmd.config.tmtc import (
|
|
|
|
tmtc_definitions_provider,
|
|
|
|
TmtcDefinitionWrapper,
|
|
|
|
OpCodeEntry,
|
|
|
|
)
|
2024-05-08 10:49:20 +02:00
|
|
|
from tmtccmd.fsfw.tmtc_printer import get_validity_buffer_str
|
2023-11-10 19:23:06 +01:00
|
|
|
from tmtccmd.tmtc import DefaultPusQueueHelper
|
|
|
|
from tmtccmd.pus.s200_fsfw_mode import Mode, pack_mode_data
|
|
|
|
from tmtccmd.pus.tc.s3_fsfw_hk import create_request_one_hk_command, make_sid
|
2022-07-08 16:25:46 +02:00
|
|
|
from tmtccmd.util import ObjectIdU32
|
2021-01-10 11:42:06 +01:00
|
|
|
|
|
|
|
|
2023-11-22 10:17:05 +01:00
|
|
|
class CmdStr:
|
2023-02-06 14:44:37 +01:00
|
|
|
OFF = "off"
|
|
|
|
ON = "on"
|
|
|
|
NML = "nml"
|
|
|
|
HK = "hk"
|
2022-01-18 14:03:56 +01:00
|
|
|
|
2023-02-06 14:44:37 +01:00
|
|
|
|
2023-11-22 10:17:05 +01:00
|
|
|
class CmdInfo:
|
2023-02-06 14:44:37 +01:00
|
|
|
OFF = "Off"
|
|
|
|
ON = "On"
|
|
|
|
NML = "Normal"
|
|
|
|
HK = "HK"
|
2021-01-10 11:42:06 +01:00
|
|
|
|
|
|
|
|
2023-01-16 17:11:20 +01:00
|
|
|
class Tmp1075ActionId(enum.IntEnum):
|
|
|
|
GET_TEMP = 1
|
|
|
|
START_ADC_CONV = 2
|
2021-01-10 11:42:06 +01:00
|
|
|
|
|
|
|
|
2023-03-16 11:21:40 +01:00
|
|
|
class SetId(enum.IntEnum):
|
2023-03-06 10:26:58 +01:00
|
|
|
TEMPERATURE = 1
|
2023-02-06 14:44:37 +01:00
|
|
|
|
|
|
|
|
2022-08-08 16:32:18 +02:00
|
|
|
def pack_tmp1075_test_into(
|
2023-11-22 10:17:05 +01:00
|
|
|
object_id: ObjectIdU32, cmd_str: str, q: DefaultPusQueueHelper
|
2022-08-08 16:32:18 +02:00
|
|
|
):
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd(
|
2023-02-06 14:49:50 +01:00
|
|
|
f"Testing Tmp1075 Temperature Sensor Handler with object id: {object_id}"
|
2021-03-19 17:50:09 +01:00
|
|
|
)
|
2022-07-04 15:22:53 +02:00
|
|
|
obyt = object_id.as_bytes
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.OFF:
|
2023-02-06 14:44:37 +01:00
|
|
|
q.add_log_cmd("TMP1075: Set Normal Off")
|
|
|
|
mode_data = pack_mode_data(obyt, Mode.OFF, 0)
|
|
|
|
q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data))
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.NML:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("TMP1075: Set Mode Normal")
|
2023-01-16 15:05:33 +01:00
|
|
|
mode_data = pack_mode_data(obyt, Mode.NORMAL, 0)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data))
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.ON:
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_log_cmd("TMP1075: Set Mode On")
|
2023-01-16 15:05:33 +01:00
|
|
|
mode_data = pack_mode_data(obyt, Mode.ON, 0)
|
2022-07-04 15:22:53 +02:00
|
|
|
q.add_pus_tc(PusTelecommand(service=200, subservice=1, app_data=mode_data))
|
2023-11-22 10:17:05 +01:00
|
|
|
if cmd_str == CmdStr.HK:
|
2023-02-06 14:44:37 +01:00
|
|
|
q.add_log_cmd("TMP1075: Request One-Shot HK")
|
2023-03-06 10:36:08 +01:00
|
|
|
q.add_pus_tc(create_request_one_hk_command(make_sid(obyt, SetId.TEMPERATURE)))
|
2022-07-04 15:22:53 +02:00
|
|
|
return q
|
2023-02-06 14:44:37 +01:00
|
|
|
|
|
|
|
|
2023-11-28 17:41:46 +01:00
|
|
|
def create_tmp_sens_node() -> CmdTreeNode:
|
|
|
|
node = CmdTreeNode("tmp_1075", "TMP1075 Temperatur Sensors")
|
|
|
|
node.add_child(CmdTreeNode(CmdStr.OFF, CmdInfo.OFF))
|
|
|
|
node.add_child(CmdTreeNode(CmdStr.ON, CmdInfo.ON))
|
|
|
|
node.add_child(CmdTreeNode(CmdStr.NML, CmdInfo.NML))
|
|
|
|
node.add_child(CmdTreeNode(CmdStr.HK, CmdInfo.HK))
|
|
|
|
return node
|
|
|
|
|
|
|
|
|
2023-02-06 14:44:37 +01:00
|
|
|
@tmtc_definitions_provider
|
|
|
|
def add_tmp_sens_cmds(defs: TmtcDefinitionWrapper):
|
|
|
|
oce = OpCodeEntry()
|
2023-11-22 10:17:05 +01:00
|
|
|
oce.add(CmdStr.OFF, CmdInfo.OFF)
|
|
|
|
oce.add(CmdStr.ON, CmdInfo.ON)
|
|
|
|
oce.add(CmdStr.NML, CmdInfo.NML)
|
|
|
|
oce.add(CmdStr.HK, CmdInfo.HK)
|
2023-02-06 14:44:37 +01:00
|
|
|
defs.add_service(CustomServiceList.TMP1075.value, "TMP1075 Temperature Sensor", oce)
|
2023-06-18 13:30:45 +02:00
|
|
|
|
|
|
|
|
|
|
|
def handle_tmp_1075_hk_data(set_id: int, hk_data: bytes, pw: PrintWrapper):
|
|
|
|
if set_id == SetId.TEMPERATURE:
|
|
|
|
temp = struct.unpack("!f", hk_data[0:4])[0]
|
|
|
|
pw.dlog(f"TMP1075 Temperature: {temp}")
|
2024-05-08 10:49:20 +02:00
|
|
|
pw.dlog(get_validity_buffer_str(hk_data[4:], 1))
|